7 research outputs found
Formation of singularities for equivariant 2+1 dimensional wave maps into the two-sphere
In this paper we report on numerical studies of the Cauchy problem for
equivariant wave maps from 2+1 dimensional Minkowski spacetime into the
two-sphere. Our results provide strong evidence for the conjecture that large
energy initial data develop singularities in finite time and that singularity
formation has the universal form of adiabatic shrinking of the degree-one
harmonic map from into .Comment: 14 pages, 5 figures, final version to be published in Nonlinearit
Dispersion and collapse of wave maps
We study numerically the Cauchy problem for equivariant wave maps from 3+1
Minkowski spacetime into the 3-sphere. On the basis of numerical evidence
combined with stability analysis of self-similar solutions we formulate two
conjectures. The first conjecture states that singularities which are produced
in the evolution of sufficiently large initial data are approached in a
universal manner given by the profile of a stable self-similar solution. The
second conjecture states that the codimension-one stable manifold of a
self-similar solution with exactly one instability determines the threshold of
singularity formation for a large class of initial data. Our results can be
considered as a toy-model for some aspects of the critical behavior in
formation of black holes.Comment: 14 pages, Latex, 9 eps figures included, typos correcte
Bifurcation and fine structure phenomena in critical collapse of a self-gravitating -field
Building on previous work on the critical behavior in gravitational collapse
of the self-gravitating SU(2) -field and using high precision numerical
methods we uncover a fine structure hidden in a narrow window of parameter
space. We argue that this numerical finding has a natural explanation within a
dynamical system framework of critical collapse
APPLICATION OF IMAGE ANALYSIS METHODS FOR ISOCENTER QUALITY ASSURANCE IN RADIOTHERAPY
One of the major procedures for testing the geometrical accuracy of devices used in radiotherapy treatments is the test of the geometrical position of the radiation isocenter. The importance of the test reflects the fact that geometrical position of the radiation isocenter generally affects the tumor targeting. At present the geometric accuracy is assessed with the Winston-Lutz test which checks the position of an image of a ball marker with the respect to the center of the radiation field as projected on a detector plane. Obviously, determination of coordinates of a single marker is not sufficient to fully account for a complicated geometry of a therapeutic device. The purpose of the study was to design a new image analysis tool to better determine the isocenter. The proposed automated procedure for determining isocenter position uses projection data acquired for a special cube phantom. The projection images of a phantom are acquired for various angles of rotation of the gantry. A procedure is proposed to extract some geometric characteristics of a therapeutic device from the projection images
APPLICATION OF IMAGE ANALYSIS METHODS FOR ISOCENTER QUALITY ASSURANCE IN RADIOTHERAPY
One of the major procedures for testing the geometrical accuracy of devices used in radiotherapy treatments is the test of the geometrical position of the radiation isocenter. The importance of the test reflects the fact that geometrical position of the radiation isocenter generally affects the tumor targeting. At present the geometric accuracy is assessed with the Winston-Lutz test which checks the position of an image of a ball marker with the respect to the center of the radiation field as projected on a detector plane. Obviously, determination of coordinates of a single marker is not sufficient to fully account for a complicated geometry of a therapeutic device. The purpose of the study was to design a new image analysis tool to better determine the isocenter. The proposed automated procedure for determining isocenter position uses projection data acquired for a special cube phantom. The projection images of a phantom are acquired for various angles of rotation of the gantry. A procedure is proposed to extract some geometric characteristics of a therapeutic device from the projection images